The
operation principle of the Hall sensor is based on the
conversion of the induction of the constant or alternating
magnetic field into the voltage proportional to it. The sensor
ensures high sensitivity to the magnetic field.
AREAS
OF APPLICATION:
Household electrical counters;
Devices of electron ignition;
Current detectors;
Systems of household and industrial automatic equipment.
SPECIFICATIONS
Parameter
Parameter
value
gr.
A
gr.
B
Specific
current sensitivity, KBI,
V/A·T
200÷600
600÷1000
Output
voltage at Inom=1mA and
B=0.1 T, Uoutput, mV
20÷60
60÷100
Input
resistance, R1, kOm, no
more than
2,1
3,0
Output
resistance, R2, kOm, no
more than
3,0
15,0
Residual
voltage at Inom=1 mA and
B=0, Vres, mV
1,5
5,0
Nominal
control current Inom, mA
1,0
-
Magnetic
induction range, B, T
from
-1 to +1
Supply
voltage, U, V
2÷6
3÷6
Operating
temperature range, °C for a plastic case
-45
÷ +85
Operating
temperature range, °C
for a ceramic case
-60
÷ +125
DESIGN
The crystal is put on a ceramic substrate with
soldered terminals and is potted in a compound.
Weight does not exceed 0.1 g.
CURRENT
DETECTOR BASED ON THE HALL CONVERTER
The current detector is designed
for measurement of alternating and direct currents; obtaining
a feedback signal in systems of automatic control of parameters
of technical systems; application in systems of control
of electricity consumption and account of electric energy,
e.g. in electricity meters.
The main element of the detector is a highly sensitive
thermostable Hall converter based on gallium arsenide,
whose output signal is proportional to the current measured.
MAJOR
ADVANTAGES
High sensitivity
A wide measurement range
Improved reliability
Simplicity in operation
Efficiency
Low cost
Noise immunity
Increased immunity to dirt and dust
SPECIFICATIONS
Measurement
current range, A
0÷50
0÷200
Measurement
accuracy, no less than, %
1
Operating
temperature range, °C
-50
÷ +60
Supply
voltage, V
5
Consumed
current, no more than, mA
10
Band
width, kHz
0÷300
Linearity,%
±0,5
Dimensions,
mm
45х25х12
The
presence of three external output signals of various
shape
ROTATION
FRECUENCY DETECTOR
The
rotation frequency detector is designed for measuring
the instantaneous frequency (or speed) of rotation of
shafts, rotors of turbines and other rotating units and
mechanisms in automatic control systems. Its basic element
is a special Hall's converter, which produces a signal
proportional to the frequency of rotation.
Number
of pulses per revolution
72
Pulse
duration
7
µs
Measurement
accuracy
no
less than 1%
Range
of operating temperatures
-50
÷ +60°С
Consumed
current
no
more than 10 mA
Supply
voltage
5
or 12 V
Service
life at non-stop rotation with a frequency of 6000
rev/mino
no
less than 10 000 hrs
MAJOR
ADVANTAGES
Absence of time lag
Noise immunity
Increased immunity to dirt and dust
Simplicity in operation
Improved reliability
A wide measurement range
Efficiency
Low cost